Blower selection starts with the amount of air required at the pressure or vacuum the system actually creates. Add electrical supply, site conditions and operating environment, then select a model whose published curve covers that operating point with appropriate margin. Flow alone is never enough, because delivered flow falls as system pressure rises.
Start with the diffuser manufacturer’s airflow requirement and the number of diffusers. Then work out the pressure: submergence, diffuser loss, piping and fitting loss, and a fouling margin. As a rough physical relationship, one foot of water depth is approximately 12 inches of water column before other system losses are added. For reference, 27.7 inches of water gauge equals 1 PSIG.
A model that reaches the duty point on the flow curve can still be running too hot. Per the manufacturer, motor winding temperature, meaning rise plus ambient, should not exceed 140°C for Class F or 120°C for Class B, and blower outlet air temperature should not exceed 140°C. Published curve maximum points assume 40°C inlet and ambient temperature; above that, consult the factory.